Berlin-Wannsee:

BER I – BERLINER EXPERIMENTIER-REAKTOR I

BER I – BERLIN EXPERIMENTAL REACTOR I

Der Berliner Experimentier-Reaktor I ging am 24. Juli 1958 am Wannsee in Betrieb, noch vor der Gründung des Hahn-Meitner-Instituts. Der 50-Kilowatt-Lösungsreaktor diente kernchemischen Experimenten, Aktivierungsanalysen und der Untersuchung von Strahlenwirkungen. Nach einem Störfall wurde er 1972 abgeschaltet. Reaktortank und weitere Teile sind im Untergeschoss einbetoniert und von einem Laborgebäude überbaut.

Berlin Experimental Reactor I began operating at Wannsee on 24 July 1958, before the Hahn-Meitner Institute was founded. The 50-kilowatt solution reactor was used for experiments in nuclear chemistry, activation analysis and investigations into the effects of radiation. Following an incident, it was shut down in 1972. The reactor tank and other components remain encased in concrete in the basement, beneath a laboratory building subsequently constructed above them.

Der BER I gehörte zur Bauart der homogenen Lösungsreaktoren, auch Water-Boiler-Reaktoren genannt. Der Kernbrennstoff befand sich in einer wässrigen Lösung. Bei lediglich 50 Kilowatt thermischer Leistung war die Anlage ein überschaubares experimentelles Werkzeug für die Kernchemie. Forschende untersuchten Spaltprodukte, aktivierten Proben mit Neutronen und bestimmten die Wirkung ionisierender Strahlung auf unterschiedliche Materialien.

Der Reaktor erreichte am 24. Juli 1958 die Kritikalität und bildete das erste technische Zentrum des späteren Instituts. Ein Schaden am Rekombinator, der das bei der Radiolyse des Wassers entstehende Wasserstoff-Sauerstoff-Gemisch wieder vereinigte, führte im Sommer 1972 zur Stilllegung. Der flüssige Kernbrennstoff wurde entfernt, und oberirdische Anlagenteile wurden beseitigt. Reaktortank, Rekombinationssystem und Teile des Primärkreislaufs verblieben im Keller. Sie wurden in einen Betonblock eingeschlossen und mit einem Laborgebäude überbaut. Im Unterschied zum 2009 vollständig beseitigten Forschungsreaktor MERLIN in Jülich wurde der BER I nicht bis zur „grünen Wiese“ zurückgebaut. Über die Finanzierung der endgültigen Entfernung der verbliebenen Anlagenteile stritten später Bund und Land Berlin.

BER I belonged to the class of homogeneous solution reactors, also known as water-boiler reactors. The nuclear fuel was dissolved in water. With a thermal output of just 50 kilowatts, the facility was a relatively modest experimental instrument for nuclear chemistry. Researchers studied fission products, irradiated samples with neutrons for activation analysis, and investigated the effects of ionising radiation on different materials.

The reactor first reached criticality on 24 July 1958 and became the first technical centre of what would later become the institute. Damage to the recombiner, which recombined the hydrogen and oxygen produced by radiolysis of the water, led to shutdown in the summer of 1972. The liquid nuclear fuel was removed, along with above-ground plant components. The reactor tank, recombination system and parts of the primary circuit remained in the basement. They were enclosed in a concrete block, and a laboratory building was constructed above them. Unlike the MERLIN research reactor in Jülich, which had been completely removed by 2009, BER I was not dismantled to a cleared site. The federal government and the state of Berlin subsequently disputed responsibility for funding the final removal of the remaining components.

Technische EckdatenKey facts
Reaktortyp
Homogener Lösungsreaktor
Bauart / Modell
Water Boiler
Hersteller
AEG / Pintsch Bamag / Siemens-Schuckertwerke
Betreiber
Hahn-Meitner-Institut Berlin
Leistung thermisch
50 kW
Erstkritikalität
24.7.1958
Rückbau
Stilllegung 1972 nach Störfall am Rekombinator; sicherer Einschluss der einbetonierten Restkomponenten
Status
sicherer Einschluss
Hauptlieferant: North American Aviation (Atomics International)
Technische EckdatenKey facts
Reactor type
Homogeneous solution reactor
Design / model
Water Boiler
Manufacturer
AEG / Pintsch Bamag / Siemens-Schuckertwerke
Operator
Hahn-Meitner-Institut Berlin
Thermal output
50 kW
First criticality
24 July 1958
Decommissioning
Shutdown in 1972 following an incident involving the recombiner; remaining components encased in concrete under safe enclosure
Status
safe enclosure
Main supplier: North American Aviation (Atomics International)