Isar:

KERNKRAFTWERK NIEDERAICHBACH

NIEDERAICHBACH NUCLEAR POWER PLANT

Das von Siemens entwickelte Kernkraftwerk Niederaichbach war ein schwerwassermoderierter, mit Kohlendioxid gekühlter Druckröhrenreaktor. Es erreichte Ende 1972 die Kritikalität, erzeugte aber nur während weniger kurzer Betriebsphasen Strom. Technische Schwierigkeiten an den Dampferzeugern führten 1974 zur endgültigen Abschaltung. 1995 war der Reaktor vollständig abgebaut.

Developed by Siemens, the Niederaichbach nuclear power plant used a pressure-tube reactor moderated by heavy water and cooled by carbon dioxide. It first achieved criticality in late 1972 but generated electricity only during a few brief operating periods. Technical problems with the steam generators led to permanent shutdown in 1974. The reactor had been completely dismantled by 1995.

Siemens entwickelte für Niederaichbach einen schwerwassermoderierten, gasgekühlten Druckröhrenreaktor. Sein Aufbau sollte eine eigenständige deutsche Kraftwerkslinie ermöglichen: Einzelne Druckröhren enthielten die Brennelemente und wurden von Kohlendioxid zur Wärmeabfuhr durchströmt; schweres Wasser diente als Moderator. Das ursprüngliche Konzept sah Natururan als Brennstoff vor und versprach damit Unabhängigkeit von importiertem angereichertem Uran. Die Gesellschaft für die Entwicklung der Atomkraft in Bayern beauftragte Siemens 1966 mit dem Bau. Den nuklearen Teil finanzierte und übernahm die Karlsruher Gesellschaft für Kernforschung, während für den konventionellen Kraftwerksteil die Bayernwerk-Tochter Kernkraftwerk Niederaichbach GmbH gegründet wurde. Die elektrische Nettoleistung war auf 100 Megawatt ausgelegt.

Am 17. Dezember 1972 erreichte der Reaktor erstmals die Kritikalität. Beim anschließenden Probebetrieb traten thermische Instabilitäten an den Dampferzeugern auf. Einbauten zur Begrenzung dieser Effekte reduzierten die erreichbare Leistung erheblich; ein Austausch der Dampferzeuger hätte das Projekt weitere Jahre verzögert. Niederaichbach erreichte im gesamten Probebetrieb nur rund 18 Volllasttage. Am 31. Juli 1974 wurde das Kraftwerk endgültig abgeschaltet.

Nach einer Phase des sicheren Einschlusses übernahm das Kernforschungszentrum Karlsruhe den vollständigen Abbau. Reaktorgebäude und Anlagenteile wurden entfernt; am 17. August 1995 endete die atomrechtliche Überwachung. Es war eines der ersten vollständigen Rückbauprojekte eines Kernkraftwerks dieser Größenordnung.

Siemens developed a heavy-water-moderated, gas-cooled pressure-tube reactor for Niederaichbach. Its configuration was intended to establish an independent German reactor design: individual pressure tubes contained the fuel elements and were traversed by carbon dioxide to remove heat, while heavy water served as the moderator. The original concept envisaged natural uranium as fuel, promising independence from imports of enriched uranium. In 1966, the Gesellschaft für die Entwicklung der Atomkraft in Bayern commissioned Siemens to build the plant. Karlsruhe's Gesellschaft für Kernforschung financed and took responsibility for the nuclear section, while the Bayernwerk subsidiary Kernkraftwerk Niederaichbach GmbH was established for the conventional power-station section. The intended net electrical output was 100 megawatts.

The reactor first achieved criticality on 17 December 1972. During subsequent trial operation, thermal instabilities occurred in the steam generators. Components installed to limit these effects substantially reduced the attainable power; replacing the steam generators would have delayed the project by several more years. Across its entire trial-operation period, Niederaichbach accumulated only approximately 18 full-load days. The plant was permanently shut down on 31 July 1974.

After a period of safe enclosure, the Karlsruhe Nuclear Research Centre undertook complete dismantling. The reactor building and plant components were removed, and regulatory control under nuclear law ended on 17 August 1995. It was among the first complete dismantling projects for a nuclear power station of this size.

Technische EckdatenKey facts
Reaktortyp
Schwerwassermoderierter, CO₂-gekühlter Druckröhrenreaktor
Hersteller
Siemens
Betreiber
Forschungszentrum Karlsruhe
Leistung elektrisch
106 MW brutto / 100 MW netto
Erstkritikalität
17.12.1972
Abschaltung
31.7.1974
Rückbau
vollständiger Rückbau und atomrechtliche Entlassung 17.8.1995
Status
rückgebaut
Probebetrieb 1973/74
insgesamt rund 18 Volllasttage
Technische EckdatenKey facts
Reactor type
Heavy-water-moderated, CO₂-cooled pressure-tube reactor
Manufacturer
Siemens
Operator
Forschungszentrum Karlsruhe
Electrical output
106 MW gross / 100 MW net
First criticality
17 December 1972
Shutdown
31 July 1974
Dismantling
completed; released from nuclear regulatory control 17 August 1995
Status
dismantled
Trial operation 1973/74
Approximately 18 full-load days in total

Glossar:Glossary:

Schwerwasserreaktor

Kernreaktor, der schweres Wasser (D₂O) als Moderator zur Abbremsung der Neutronen verwendet. Das Kühlmittel muss dagegen nicht aus schwerem Wasser bestehen. Beim MZFR in Karlsruhe und den Atucha-Reaktoren in Argentinien diente schweres Wasser sowohl zur Moderation als auch zur Kühlung; beide sind Druckwasserreaktoren mit Reaktordruckbehälter. Niederaichbach und Lucens waren hingegen schwerwassermoderierte, mit Kohlendioxid gekühlte Druckröhrenreaktoren. Auch die kanadischen CANDU-Reaktoren besitzen Druckröhren; bei ihnen wird schweres Wasser sowohl als Moderator als auch als Kühlmittel verwendet, in getrennten Kreisläufen.

Glossar:Glossary:

Heavy-Water Reactor

A nuclear reactor that uses heavy water (D₂O) as a moderator to slow neutrons. The coolant does not, however, have to be heavy water. At the MZFR in Karlsruhe and the Atucha reactors in Argentina, heavy water served both as moderator and coolant; both are pressurised water reactors with reactor pressure vessels. Niederaichbach and Lucens, by contrast, were heavy-water-moderated, carbon-dioxide-cooled pressure-tube reactors. Canadian CANDU reactors also have pressure tubes; they use heavy water as both moderator and coolant, in separate circuits.