VERSUCHSATOMKRAFTWERK LUCENS

LUCENS EXPERIMENTAL NUCLEAR POWER PLANT

In Lucens im Kanton Waadt entstand in einer Felskaverne ein Schweizer Versuchsatomkraftwerk. Sein schwerwassermoderierter, mit Kohlendioxid gekühlter Druckröhrenreaktor verwendete schwach angereichertes Uranmetall und sollte den Weg zu einem eigenständigen Schweizer Kernkraftwerkstyp eröffnen. Beim Wiederanfahren am 21. Januar 1969 kam es zu einer teilweisen Brennstoffschmelze. Die Anlage wurde aufgegeben; die Reaktorkaverne ist heute mit Beton verfüllt.

An experimental Swiss nuclear power plant was built in a rock cavern at Lucens in the canton of Vaud. Its heavy-water-moderated, carbon-dioxide-cooled pressure-tube reactor used slightly enriched uranium metal and was intended to pave the way for an independent Swiss reactor design. During a restart on 21 January 1969, part of the fuel melted. The project was abandoned; the reactor cavern has since been filled with concrete.

Der Schweizer Kraftwerksversuch

Nach dem aus den USA übernommenen SAPHIR und dem selbst entwickelten Forschungsreaktor DIORIT wollte die Schweiz auch einen eigenen Leistungsreaktor bauen. Die Nutzung von schwerem Wasser und nur schwach angereichertem Uran sollte die Abhängigkeit von importierter Leichtwasser-Reaktortechnik und hochangereichertem Brennstoff begrenzen. Für Lucens entstand ein mit Kohlendioxid gekühlter Druckröhrenreaktor in einer unterirdischen Felskaverne. Der Brennstoff bestand aus Uranmetall mit 0,96 % Uran-235, umhüllt von einer Magnesiumlegierung. Ein verwandtes schwerwassermoderiertes, gasgekühltes Druckröhrenkonzept wurde in der Bundesrepublik mit Niederaichbach erprobt.

Am 29. Dezember 1966 erreichte Lucens erstmals die Kritikalität. 1967 folgten Inbetriebsetzungsversuche. Im Jahr 1968 wurde die Leistung schrittweise gesteigert; im Sommer und Herbst erreichte die Anlage zeitweilig ihre thermische Nennleistung von etwa 30 Megawatt.

Die Teilkernschmelze vom 21. Januar 1969

Während einer vorausgegangenen Stillstandsphase war durch eine schadhafte Dichtung Wasser in den Kohlendioxid-Kühlkreislauf gelangt. Es verursachte Korrosion an den Magnesiumhüllen einzelner Brennstäbe. Die Korrosionsprodukte verengten die Kühlkanäle. Als der Reaktor am 21. Januar 1969 beim Wiederanfahren etwa zwölf Megawatt erreichte, überhitzte Brennelement 59; Teile des Urans und seiner Hülle schmolzen und gerieten in Brand. Die automatische Schnellabschaltung beendete die Kettenreaktion, während der Brand fortdauerte.

Durch die Hitze verformte sich die Graphitstruktur um das Brennelement. Das betroffene Druckrohr überhitzte und barst. Der Druckstoß beschädigte den Moderatortank und ließ dessen Berstmembranen reißen. Schweres Wasser, Uran-Magnesium-Schmelze und radioaktiv kontaminiertes Kühlgas wurden in die Reaktorkaverne geschleudert; geringere Mengen gelangten in die angrenzende Maschinenkaverne. Die radiologischen Auswirkungen auf Personal und Umgebung blieben nach den späteren Untersuchungen gering.

Rückbau und Nachnutzung

Nach dem Unfall wurde das Projekt aufgegeben. Die Zerlegung des Reaktors und die Dekontaminationsarbeiten waren bis Ende 1974 weitgehend abgeschlossen. 1991 bis 1993 wurden die Reaktorkaverne und weitere Teile der Anlage mit Beton verfüllt. Andere Bereiche des ehemaligen Kavernenkomplexes dienen dem Kanton Waadt heute als Depot für Kulturgüter.

Lucens beendete den Versuch, einen eigenen Schweizer Schwerwasser-Leistungsreaktor zur Marktreife zu bringen. Das technische Gegenstück Niederaichbach wurde in Deutschland nach wenigen Betriebsmonaten 1974 ebenfalls endgültig abgeschaltet. Für das spätere Schweizer Kernkraftwerk Gösgen wurde ein Druckwasserreaktor der deutschen Kraftwerk Union beschafft.

Switzerland's experimental power reactor

After importing the SAPHIR research reactor from the United States and developing its own DIORIT research reactor, Switzerland also sought to build an indigenous power reactor. Heavy water and only slightly enriched uranium were intended to reduce dependence on imported light-water reactor technology and highly enriched fuel. The result at Lucens was a carbon-dioxide-cooled pressure-tube reactor housed in an underground rock cavern. Its fuel consisted of uranium metal enriched to 0.96% uranium-235, clad in a magnesium alloy. A related heavy-water-moderated, gas-cooled pressure-tube concept was tested in West Germany at Niederaichbach.

Lucens first achieved criticality on 29 December 1966. Commissioning tests followed in 1967. During 1968, power was increased in stages; in the summer and autumn the plant intermittently reached its rated thermal output of approximately 30 megawatts.

Partial core meltdown on 21 January 1969

During an earlier shutdown, water had entered the carbon dioxide cooling circuit through a defective seal. It caused corrosion of the magnesium cladding on some fuel rods. Corrosion products narrowed the coolant channels. When the reactor reached approximately twelve megawatts during a restart on 21 January 1969, fuel element 59 overheated. Parts of its uranium and cladding melted and caught fire. The automatic reactor scram stopped the chain reaction, but the fire continued.

The heat distorted the graphite structure around the fuel element. The affected pressure tube overheated and burst. The pressure surge damaged the moderator tank and ruptured its bursting discs. Heavy water, molten uranium and magnesium, and radioactively contaminated coolant gas were expelled into the reactor cavern; smaller quantities reached the adjoining machinery cavern. Subsequent investigations found that the radiological effects on staff and the surrounding area had been limited.

Dismantling and reuse

The project was abandoned after the accident. Dismantling of the reactor and decontamination were largely complete by the end of 1974. Between 1991 and 1993, the reactor cavern and other parts of the installation were filled with concrete. Other sections of the former cavern complex are now used by the canton of Vaud to store cultural property.

Lucens marked the end of attempts to bring an indigenous Swiss heavy-water power reactor to commercial maturity. Its technological counterpart at Niederaichbach in Germany was also permanently shut down in 1974, after just a few months of operation. Switzerland subsequently ordered a pressurised water reactor from the German Kraftwerk Union for the Gösgen nuclear power plant.

Technische EckdatenKey facts
Reaktortyp
Schwerwassermoderierter, CO₂-gekühlter Druckröhrenreaktor
Hersteller
Therm-Atom
Betreiber
Nationale Gesellschaft zur Förderung der Industriellen Atomtechnik (NGA)
Leistung thermisch
rund 30 MW Nennleistung
Erstkritikalität
29.12.1966
Status
rückgebaut
Uranmetall mit 0,96 % U-235
Versuchsbetrieb 1967/68
Teilkernschmelze und endgültige Abschaltung 21.1.1969
Zerlegung/Dekontamination bis 1974
Verfüllung der Reaktorkaverne 1991–1993
Technische EckdatenKey facts
Reactor type
Heavy-water-moderated, CO₂-cooled pressure-tube reactor
Manufacturer
Therm-Atom
Operator
National Society for the Promotion of Industrial Nuclear Technology (NGA)
Thermal output
Rated output approximately 30 MW
First criticality
29 December 1966
Status
Dismantled
Uranium metal enriched to 0.96% U-235
Experimental operation in 1967/68
Partial core meltdown and permanent shutdown on 21 January 1969
Dismantling/decontamination largely complete by 1974